30 HE250 - Installation and Operation Manual
PART B INSTALLATION
Install the fireplace only as described in these instructions and using only components from the chimney
manufacturers listed in table 2.
Parts Required
HE250 Fireplace
Insulated chimney made by the manufacturer listed in table 2, with the corresponding specifications:
Chimney lengths
Elbows (where necessary)
Associated components as per these installation instructions.
Additional Equipment (optional)
Forced Air Distribution Kit
Hot Air Gravity Distribution Kit
Fire screen
6 SAFETY INFORMATION
6.1 Summary of Installation Cautions and Warnings
THE INFORMATION GIVEN ON THE CERTIFICATION LABEL AFFIXED TO THE APPLIANCE ALWAYS
OVERRIDES THE INFORMATION PUBLISHED, IN ANY OTHER MEDIA (OWNER’S MANUAL, CATALOGUES,
FLYERS, MAGAZINES AND/OR WEB SITES).
MIXING OF APPLIANCE COMPONENTS FROM DIFFERENT SOURCES OR MODIFYING COMPONENTS
MAY RESULT IN HAZARDOUS CONDTIONS. WHERE ANY SUCH CHANGES ARE PLANNED, STOVE
BUILDER INTERNATIONAL INC. SHOULD BE CONTACTED IN ADVANCE.
ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING
AUTHORITY VIOLATES CSA B365 (CANADA), AND ANSI NFPA 211 (USA).
CONNECTION BETWEEN A 2100 INSULATED CHIMNEY AND A LISTED STAINLESS STEEL CHIMNEY LINER
IS ALLOWED IF A LISTED CONNECTOR IS USED. FOLLOW INSTRUCTIONS AT THE SECTION 8.9 FOR THAT
KIND OF INSTALLATION.
IF REQUIRED, A SUPPLY OF COMBUSTION AIR SHALL BE PROVIDED TO THE ROOM.
DO NOT CONNECT TO OR USE IN CONJUNCTION WITH ANY AIR DISTRIBUTION DUCTWORK UNLESS
SPECIFICALLY APPROVED FOR SUCH INSTALLATION.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
THIS FIREPLACE HAS NOT BEEN TESTED TO BE INSTALLED IN A MOBILE HOME.
THIS FIREPLACE HAS NOT BEEN TESTED TO BE INSTALLED INSIDE A MASONRY CHIMNEY.