4.6.1 Explanation of Engineering Mode Features
1.Auto Start when selected ON machine will commence cycle automatically when the lid is opened & closed
for loading.
2.Service Reset Reset service count to zero following service.
3.Standard cycle 120 second cycle using 23 liters of water. Suitable for normal load conditions. Motor
reverse at start of cycle is via current detection.
4.Heavy Duty cycle 160 second cycle using 30 liters of water. Suitable for heavy loads and possible
overloaded conditions. Motor preprogrammed for 3x motor reverses at beginning of cycle.
5.ECO cycle 95 second cycle using 16.5 liters of water. Suitable for light (single product) loads.
6.Night cycle Extend version of standard cycle to reduce average dB level.
7.Water In Valve Time out time for water inlet valve. Default is 3 minutes. After 3 minutes if water tank
sensor does not detect full water tank, then inlet valve will close minimize potential water tank overflow due
to sensor failure. In low water pressure supply conditions default time can be increased to 4 minutes.
8.Service limit number of cycles before “Service due” message is displayed. Default setting is 20k cycles this
can be adjusted between 20K & 5K in 5k increments cycles.
9.Cycle Count Enables the number of recorded cycles (if known) from a machine to be entered onto a new
PCB in the event of a machine requiring a new PCB.
10.Stop on L Deo Default is off, therefore when low deodoriser level is detected “Refill deodoriser” message
is displayed however machine will continue to run cycles normally. When ON is selected further machine
cycles are prevented until the deodoriser reservoir is refilled.
11.Water Pump selecting will manually operate the water pump. This can be used to test the pump or to
quickly empty the water tank. NB ensure that the lid is closed when operating the water pump manually.
12.Deo Pump selecting will manually operate the deodoriser pump. This can be used to test or prime the
deodoriser pump.
13.Drain Valve Selecting will manually open the drain valve and allow the contents of the hopper to empty
via the drain.
14.Serial Number Allows the serial number of the machine to be saved to the PCB board.
15.Set Language - Allows the display panel to display messages in the following languages English, French,
Spanish, Portuguese, Dutch, Japanese.
16.Error Log Displays the last 5 recorded machine errors.
17.Lid Misuse Displays the total number of recorded lid misuse event. (Lid manually closed).
18.Restart Clear During a cycle if an operator clears & a fault reoccurs 3 times e.g., 3 X drain pressure faults
then a call engineer message is displayed, and the reset option is no longer presented to the operator.
Engineer must access & clear Restart Clear option from the engineer menu return machine to normal service.
(Original fault should also be investigated and corrected).
19.Misuse Clear selecting yes enables the number of lid misuse events to be reset to zero. (see also 17