NetSure
Control Unit (NCU)
User Manual, UM1M830BNA
Spec. No: 1M830BNA, 1M830DNA Code: UM1M830BNA
Model No: M830B, M830D Revision M, May 12, 2017
[23]
Programming the Audible Alarm Feature
Local Menu Navigation:
Main Menu / Settings Icon / Alarm Settings / Audible Alarm.
Web Menu Navigation:
Settings Menu / System Tab / LCD Audible Alarm.
Manually Forcing LVDs
Local Menu Navigation:
Main Menu / Settings Icon / Maintenance / “Auto/Man” State
(change to Manual).
then
Main Menu / Settings Icon / Maintenance / LVD 1 Control or LVD 2
Control (select the other state).
then
Main Menu / Settings Icon / Maintenance / LVD 1 Control or LVD 2
Control (select the original state).
then
Main Menu / Settings Icon / Maintenance / “Auto/Man” State
(change to Auto).
Web Menu Navigation:
Settings Menu / System Tab / “Auto/Manual” State (change to
Manual).
then
Settings Menu / LVD Tab / LVD 1 Control or LVD 2 Control (select
the other state).
then
Settings Menu / LVD Tab / LVD 1 Control or LVD 2 Control (select
the original state).
then
Settings Menu / System Tab / “Auto/Manual” State (change to
Auto).
Manually Forcing Relays
After completing the following steps, the relay will momentarily
toggle to the chosen state. The relay then reverts back to being
controlled by the NCU.
NOTE: This may take a few minutes.
See also “Using the Relay Test Feature” on page 28.
Local Menu Navigation:
None.
WEB Menu Navigation:
Settings Menu / System Tab / “Auto/Manual” State (change to
Manual).
then
Advance Settings Menu / DO (relay) / Relay (select the other state)
then press the SET button.
then
Settings Menu / System Tab / Power System / “Auto/Manual” State
(change to Auto).
Assigning Severity Level to Alarms
Local Menu Navigation:
None.
Web Menu Navigation:
Advance Settings Menu / Alarms Tab and DI Alarms Tab.
Assigning Relays to Alarms
Local Menu Navigation:
None.
Web Menu Navigation:
Advance Settings Menu / Alarms Tab and DI Alarms Tab.
Placing the System in Float or Equalize Charge Mode
Local Menu Navigation:
Main Menu / Settings Icon / Maintenance / “EQ/FLT Control”.
Web Menu Navigation:
Settings Menu / Battery Tab / “Equalize/Float” Charge Control.
Viewing/Changing the Float Voltage Setting
Local Menu Navigation:
Main Menu / Settings Icon / Batt Settings / Charge / Float Voltage.
Web Menu Navigation:
Settings Menu / Battery Tab / Float Charge Voltage.
Viewing/Changing the Equalize Voltage Setting
Local Menu Navigation:
Main Menu / Settings Icon / Batt Settings / Charge / EQ Voltage.
Web Menu Navigation:
Settings Menu / Battery Tab / Equalize Charge Voltage.

Table of Contents

Other manuals for Vertiv Netsure

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vertiv Netsure and is the answer not in the manual?

Vertiv Netsure Specifications

General IconGeneral
BrandVertiv
SeriesNetsure
Humidity Range5% to 95% non-condensing
Cooling MethodForced air
Communication InterfaceEthernet
Protection FeaturesOvervoltage, overcurrent, short circuit, overtemperature

Related product manuals