iPM 200 generator module
® Vetaphone March 2021 3401201GB
Self-test (Power Stage
error)
(Only exists in Firmware version
5.21 and up)
if this error persists the generator is defect, contact support
department
Generator defect. Contact the support department
This error can occur due to high surge or burst pulses on the
mains supply lines.
Reset the error and wait 10 seconds and try again.
If the error persists, contact the support department
Clean insulators and electrode and adjust electrode.
Can also be caused by a flash over or defective cable (check
cables)
Reset the error and wait 10 seconds and try again.
If the error persists, contact the support department
Check input supply voltage are within range 380-520Vac
The output power has been
lower than minimum limit
for more than 3 seconds.
Reset the error, if the error persists contact the support
department.
Clean electrode and insulators, 80% of E-30 errors are
caused by this. Check for flashover, flame or electrode
adjustment.
For electrode adjustment, see station manual.
This is a customer specific error code and mean different
things.
The codes meaning is determent in agreement with the
customer.
This is a customer specific error code and means different
things.
The codes meaning is determent in agreement with the
customer.
This is a customer specific error code and means different
things.
The codes meaning is determent in agreement with the
customer.
This is a customer specific error code and can mean different
things.
Typically, the error code shows cartridge is missing/not
detected when cartridge sensors (dummy cartridge) are
installed. Check the distance between sensor and cartridge
(should be 1 mm).
The code meaning is determent in agreement with the
customer.
If the error persists, contact the support department.