EasyManua.ls Logo

Videx 4000 Series - Page 38

Videx 4000 Series
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
66250754-EN - V1.0 - 18/02/19
- 38 -
4000 Series GSM Audio Intercom - Technical Manual
4000 Series GSM Audio Intercom with Proximity
Programming the GSM Intercom
Store master telephone no. STM 1111STM”07771234567” n/a n/a 46
Latch the relay RLA 1111RLA n/a n/a 46
Unlatch the relay RUL 1111RUL n/a n/a 46
Latch the auxiliary AO1 output A1L 1111A1L n/a n/a 46
Unlatch the auxiliary AO1 output A1U 1111A1U n/a n/a 46
Latch the auxiliary AO2 output A2L 1111A2L n/a n/a 46 - 47
Unlatch the auxiliary AO2 output A2U 1111A2U n/a n/a 47
Store timeband for call buttons
to be active for
TBA 1111TBA”HHMMHHMM”,days HHMMHHMM
days = Mo, Tu, We,
Th, Fr, Sa, Su, AD,
WD and WE
00002359
AD (all days)
47
Store timeband(s) for access
control: proximity, access codes
and dial to open numbers to be
active for
ATB 1111ATBn”HHMMHHMM”,days n = 0 - 9
HHMMHHMM
days = Mo, Tu, We,
Th, Fr, Sa, Su, AD,
WD and WE
n/a 47 - 48
Store access levels for access
control: proximity, access codes
and dial to open numbers to be
active for
ACC 1111ACCn”tttttttttt”,rrrrrrrr n = 0 - 9
each t = 1 or 0
each r = 1 or 0
n/a 49
Using access levels with dial to
open numbers (DTO)
STR 1111STR”n1”An,n2”An,n3”An,n4
An,n5”An
An = A0 - A9
n1 = 1st DTO
n2 = 2nd DTO
n3 = 3rd DTO
n4 = 4th DTO
n5 = 5th DTO
n/a 50
Check/Set date & time CLK 1111CLK”yy/mm/dd,hh:mm”? yy/mm/dd,hh:mm n/a 50
Input status check and set CHK 1111CHK? n/a n/a 50 - 51
Silent dialling mode AUE 1111AUEnn nn = 00 or 01 01 51
Send tone after answer (But 1) DTP 1111DTPn n = 0 - 9 or X X 51
Send tone after answer (Div 1) DTD 1111DTDn n = 0 - 9 or X X 51
Send DTMF tone delay DTT 1111DTTnn nn = 01 - 12 03 51
Enable dial 0 on answer function EDZ 1111EDZnn? nn = 00 or 01 00 51 - 52
Enable # (hash) function ED# 1111ED#nn? nn = 00 or 01 00 52
Enable proximity EPR 1111EPRnn? nn = 00 or 01 00 52
Proximity number of bytes to
check
PBY 1111PBYnn? nn = 02, 03 or 04 02 52 - 53
Store a fob/card in a known
location or the next available
location
FOB 1111FOBnnn”site,”user
or
1111FOB”site”,”user
nnn = 000 - 999 or
nnn - optional
n/a 53
Store a fob/card in a known
location or the next available
location with an access level
FOB 1111FOBnnn”site,”userAn
or
1111FOB”site”,”userAn
nnn = 000 - 999 or
nnn - optional
An = A0 - A9
An default = all
access unless
specied
53 - 54
Find a fob or card number FDF 1111FDF”user code n/a n/a 54
Delete a fob or card without
knowing its location
DEF 1111DEF”12345” n/a n/a 54
Store an access code in a known
location or the next available
location and activate relays 1
and/or 2 respectively
PIN 1111PINnnn”code”12
or
1111PIN”code”12
nnn = 000 - 399 or
nnn - optional
code = 4 - 8 digit
access code
1, 2 = relay to
activate
relay setup
default = relay 1
unless specied
54 - 55

Other manuals for Videx 4000 Series