Limiting the maximum heating output
Parameter Possible change Main display Additional display
"P03" Max. heating output in %
of the upper rated heating
output.
Setting range 40 to 100 %
Heating output
in %
Length of flue system
Parameter Possible change Main display Additional display
"P04" Correction factor for the
length of the flue system
Setting range 1 to 3
Rated heating output
≤ 24 kW
1 Length ≤ 1 m
2 Length > 1 m ≤ 3 m
3 Length > 3 m ≤ 5 m
Rated heating output
≥ 30 kW
1 Length ≤ 1 m
2 Length > 1 m ≤ 2 m
3 Length > 2 m ≤ 3 m
Correction factor
Activating WLAN module
Parameter Possible change Main display Additional display
"P06" "OFF" WLAN module
switched off
"On" WLAN module
switched on
When "ON", the
symbol appears:
Parameter
Parameter level 1
(cont.)