Standby mode
Symbols Main display Additional display
Flashing Constant
"SEt"
Parameter level 1
Calling up parameter level 1:
1. Hold down MODE and simulta-
neously for approx. 5 s.
"SEt" and flash.
"PL:1" is shown on the additional
display.
is shown in the upper display
area
2. Press MODE.
"P01" is shown on the main dis-
play.
appears.
3. Use / to select the parameter.
4. OK to confirm
Emissions test mode
Parameter Possible change Main display Additional display
"P01" "OFF" Test mode switch-
ed off
"On" Test mode switch-
ed on
With test mode switched
on, use / to change be-
tween upper and lower
heating output.
With test mode
switched on:
Temperature
in °C
With test mode
switched on:
"LO" For lower
heating out-
put
"HI" For upper
heating out-
put
Filling and venting function
Parameter Possible change Main display Additional display
"P02" "OFF" Function switched
off
"On" Function switched
on
With test mode
switched on:
"Air"
With test mode
switched on:
Remaining time
in min
Parameter
Main parameter level
(cont.)
5837146

Table of Contents

Other manuals for Viessmann Vitopend 100-W

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Viessmann Vitopend 100-W and is the answer not in the manual?

Viessmann Vitopend 100-W Specifications

General IconGeneral
Fuel TypeGas
Max. Water Temperature85 °C
TypeCondensing Boiler
Gas TypeNatural gas / LPG
EfficiencyUp to 98%

Related product manuals