76
Displayed
fault code
System character-
istics
Cause Measures
F80 Function at the ex-
ternal extension faul-
ty
Short circuit, lower
cylinder tempera-
ture sensor S2 at
the external exten-
sion
Check sensor.
Installation and
service instruc-
tions for external
extension
F88 Function at the ex-
ternal extension faul-
ty
Lead break, lower
cylinder tempera-
ture sensor S2 at
the external exten-
sion
Check sensor.
Installation and
service instruc-
tions for external
extension
F90 Function at the ex-
ternal extension faul-
ty
Short circuit, upper
cylinder tempera-
ture sensor S3 at
the external exten-
sion
Checking the sensor
Installation and
service instruc-
tions for external
extension
F98 Function at the ex-
ternal extension faul-
ty
Lead break, upper
cylinder tempera-
ture sensor S3 at
the external exten-
sion
Check sensor.
Installation and
service instruc-
tions for external
extension
FA9 Function of Open-
Therm control unit
faulty
OpenTherm com-
munication inter-
rupted
Check OpenTherm con-
necting lead. Check set-
ting of parameter P07.