EasyManuals Logo

Viessmann Vitopend 100-W Installation And Service Instructions

Viessmann Vitopend 100-W
136 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #83 background imageLoading...
Page #83 background image
83
4. Cylinder temperature sensor
(gas system boiler):
Disconnect plug % from the con-
trol unit cable harness.
Check the sensor resistance and
compare it to the curve.
In the event of severe deviation
replace the sensor.
Checking the fuse
2.
1.
1. Switch OFF the power supply.
2. Open the control unit enclosure.
3. Check fuse F1. See page 87.
Danger
Incorrect or improperly fitted
fuses can lead to an
increased risk of fire.
Insert fuses without using
any force. Position fuses
correctly.
Only use structurally iden-
tical types with the speci-
fied response characteris-
tics.
Troubleshooting
Repairs
(cont.)
5837146
Service

Table of Contents

Other manuals for Viessmann Vitopend 100-W

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Viessmann Vitopend 100-W and is the answer not in the manual?

Viessmann Vitopend 100-W Specifications

General IconGeneral
Fuel TypeGas
Max. Water Temperature85 °C
TypeCondensing Boiler
Gas TypeNatural gas / LPG
EfficiencyUp to 98%