18
Further information can be found
in chapter "T
erminology" in the
Appendix.
Setting the standard room temperature
Operation without room temperature controller
― Setting the
heating water temperature
If no outside temperature sensor and
no room temperature controller is con-
nected.
The room temperature is influenced by
the heating water temperature. In the
delivered condition, the heating water
temperature is set to 70 °C.
Press the following buttons:
1. MODE repeatedly, until the heating
water temperature appears
on the main display
together with symbols
and , and symbol is
flashing.
°C
2. /
3. OK
for the required value.
Setting range:
20 to 80 °C
(Vitodens 100-W)
40 to 76 °C
(Vitopend 100-W)
to confirm
Room temperature-dependent operation ― Setting the set
room temperature
If no outside temperature sensor is con-
nected, but a room temperature sensor
is.
Central heating
Room temperature
5837147

Table of Contents

Other manuals for Viessmann Vitopend 100-W

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Viessmann Vitopend 100-W and is the answer not in the manual?

Viessmann Vitopend 100-W Specifications

General IconGeneral
Fuel TypeGas
Max. Water Temperature85 °C
TypeCondensing Boiler
Gas TypeNatural gas / LPG
EfficiencyUp to 98%

Related product manuals