Flue, system size 60 and 80 (components) (type B
23
to TRÖI 2009)
D
B
A
E
E
2
C
65 41
2
2
3
2
3
4
3
2
A
C
E
A
Ventilation air
Ventilation air aperture, min. 150 cm
2
or 2 × 75 cm
2
B
Flue gas
C
Inspection port
D
Connection piece
E
Secondary ventilation
System size
Ø mm
1
Boiler flue connection (part of the stand-
ard boiler delivery)
and
60/100 80/125
Balanced flue adaptor
Ø 80/125 mm to Ø 60/100 mm
60
2
Standard shaft pack (PPs, rigid)
Comprising:
Support bend
Support rail
Shaft cover (PPs)
Spacers (5 pce, max. distance 5 m)
or
60 80
Standard shaft pack (metal/PPs, rigid)
For twin flue chimneys; one flue for solid
fuel boilers
Comprising:
Support bend
Support rail
Shaft cover (metal)
Terminal pipe (stainless steel)
Spacers (5 pce, max. distance 5 m)
60 80
Spacers (3 pce, max. distance 5 m) 60 80
3
Pipe 60 80
1.95 m long (2 pce @ 1.95 m = 3.9 m)
1.95 m long (1 pce)
1 m long (1 pce)
0.5 m long (1 pce)
4
Inspection piece, straight (1 pce) 60 80
5
Bend
87º (1 pce)
45º (2 pce)
60 80
6
Ventilation bezel (1 pce) 60 80
Flue bend (for use in corbelled chim-
neys)
30º (2 pce)
15º (2 pce)
60 80
Inspection tee
87º (1 pce)
60 80
Balanced flue air inlet adaptor
Ø 80/125 mm
For installing the boiler with a balanced flue
pipe up to the shaft inlet in an installation
room where the combustion air is supplied
via interconnected rooms
60 80
Stainless steel extension
(Metal/PPs, rigid)
380 mm long for shaft cover, metal/PPs,
rigid
60 80
Max. total length of the flue up to the boiler flue connection
Rated heating output
at system temperature 50/30 °C
kW 12.9/19.3 16.1/23.5
Max. length for system size 60/100 m 16 9
Max. length for system size 80/125 m 23 23
The following components are taken into consideration for the maxi-
mum flue lengths:
Connection pipe D 0.5 m long.
1 bend 87º and 1 support bend 87º
or
2 bends 45º and 1 support bend 87º
Subtract other bends, tees and extension pieces from the maximum
length using the following values:
Connection pipe 0.5 m long: 0.5 m
Connection pipe 1 m long: 1 m
Bend 45º: 0.3 m
Bend 87º: 0.5 m
Inspection tee: 0.3 m
Design and sizing information for the Vitoladens 300-W and 333-F