Disassembly
©2009 Viking Preferred Service 43
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.
Manifold Assembly Removal
Condition Requirements:
Main Top Removed
Gas Supply Disconnected
Gas leak hazard. To avoid risk of personal injury
or death, leak testing of the appliance must
be conducted according to the manufacturer’s
instructions. Before placing appliance in operation,
always check for gas leaks with soapy water solution.
DO NOT USE AN OPEN FLAME TO CHECK FOR
GAS LEAKS.
1. Remove all IRIS modules from valves.
2. Disconnect fl ex tubing from each valve.
3. Remove three screws and manifold assembly from
range.
4. Reverse procedure for installation.
5. Perform gas leak test.
Pressure Regulator Removal
Condition Requirements:
Manifold Assembly Removed
Gas leak hazard. To avoid risk of personal injury
or death, leak testing of the appliance must
be conducted according to the manufacturer’s
instructions. Before placing appliance in operation,
always check for gas leaks with soapy water solution.
DO NOT USE AN OPEN FLAME TO CHECK FOR
GAS LEAKS.
1. Remove pressure regulator from manifold.
2. Reverse procedure for installation.
3. Perform gas leak test.
Orifi ce Removal
Condition Requirements:
None
1. Remove grates, burner cap, and burner head from
burner base assembly.
2. Remove orifi ce from jet holder.
3. Reverse procedure for installation.