21
7509 - 7509/D Tab
EN
Configuration of a button for lock release of a specific outdoor station ( , , , , )
Conguration procedure (“Simplied” mode):
Raise the handset and bring it to your ear to listen to the sound feedback emitted by the entryphone during
the conguration phase.
1. Press the button to be congured and hold it down for at least 6 s until the indoor station emits a rst “beep” followed
by another two “beeps” in sequence.
2. Continue holding down the button to be congured
After 2 s more the indoor station emits two “beeps” set apart (duration 0.5 s with a space in between).
3. Release the button being congured.
4. From the outdoor station concerned, make a call to the indoor station being congured.
5. The indoor station receives the call and conrms that the button has been conguration with a new “beep”.
beep
2
+ 2 s
3
4
*
5
< 60 s
beep
**
beep
1
> 6 s
*