Chapter 5 - Maintenance 59
Use a flat blade
screwdriver to loosen the
motor brush cap. Inspect
the motor brush for length.
If the length is under 1/8
of an inch, the motor
brush needs to be
replaced. See figure 5.12.
(Figure 5.12) Motor Brush & Cap
M
otor
B
rus
h
Motor Brush Cap
Motor Brush Cap
If the motor brush is over 1/8 of an inch, put the existing brush back into the motor and
replace the motor brush cap.
Next, put the three covers that you just removed back on.
leaning the Fan Filter
uld be performed to ensure reliable operation of
d
back of the VE-810.
o pop the guard open.
ter and blow out the filter with low-pressure compressed air.
C
Weekly preventative maintenance sho
your VE-810. It is recommended that the input fan filter be removed weekly and cleane
to ensure proper cooling of the electronics.
1. Unplug the power cable that goes into the
2. Remove the filter guard by using a small flat blade screwdriver t
See figure 5.13.
3. Remove the fil
4. Replace the filter and filter guard by snapping it back in place.
(Figure 5.13) Cooling fan

Questions and Answers: