8. Periodic Test by User Code
52 D-304269 KP-250 PG2 User’s Guide
8
8
8
8.
.
.
. Periodic Test
Periodic TestPeriodic Test
Periodic Test
by User Code
by User Codeby User Code
by User Code
The components of your security system are designed to be maintenance-free as much as possible. Nevertheless, it is
mandatory to test the system at least once a week and after an alarm event to verify that all system sirens, detectors,
keyfobs, keypads and other peripherals function properly. Proceed as described in this section and if there is any
problem, notify your installer at once.
The test is performed in three parts:
Siren Test: Each siren of the system is automatically activated for 3 seconds (outdoor sirens with low volume). In
addition, the system tests the siren of enrolled smoke sensors.
Temperature Sensor Test: When Temperature Sensors are enrolled in the system, the KP-250 PG2 displays the
temperature of each zone in Celsius or Fahrenheit.
Other Device Test: Each of the other devices in the system is activated by the user and the display indicates which
devices were not yet tested. The "it's me" indication helps to identify the untested devices if necessary. A counter also
indicates the number of devices that remain untested.
Carefully read the section titled "Additional Information" according to the indicated references
1
etc – see table
at end of this section.
A. To Enter the Periodic Test Menu
1.
HH:MM READY
Make sure the system is disarmed and then press the button repeatedly until
the display reads "PERIODIC TEST" and press .
1
PERIODIC
TEST
2.
PRESENT TAG OR
ENTER CODE:
The screen will now prompt you to enter your user code or present your proximity
tag.
3.
CODE/TAG
Enter your User Code or present your proximity tag.
2
3
Go to step 4
B. To Test the Sirens
4.
SIRENS TEST
The display now reads [SIREN TEST].
5.
To initiate the siren test press .
Immediately after pressing , all 4
LEDs on the panel and all 5 LEDs on the KP-250 PG2 should light (LED test).
4
SIREN P
<NEXT> or <OK>
The display now reads [SIREN P], where "P" indicates the control panel siren that
is currently being tested.
First the panel siren sounds for 3 seconds after which the PowerMaster system will
automatically repeat the procedure for the next siren enrolled in the system until all
sirens are tested.
5
You should listen to the sirens sounds and make sure that all sirens sound.