APPENDIX B: Partitioning
D-304269 KP-250 PG2 User’s Guide 61
B3. The Show Function
The show function is enabled during single/all partition
(s)
status and displays information that is relevant to the selected
or all partitions.
Show All Partitions
In Ready mode press , the display will show information on all partitions. Press repeatedly to view
memory / status content.
Show Single Partition
In Ready mode, press
and then press the partition number. The display will show information relevant to the
selected partition. Press repeatedly to view memory / status content.
Note: After 5 seconds of no button press there will be a timeout and the display will revert to the all partition display.
B4. Siren
A partition is alarmed when receiving an event from an a
larmed device assigned to that partition. Alarmed devices do
not affect partitions to which they are not assigned. A siren is common to all partitions; therefore, an alarm from one or
more partitions will activate the siren.
Siren Activity
• The siren will be activated when receiving an event from an alarmed device.
• Overlapping siren activations from different partitions w
ill not cause the duration of the siren to be extended.
• When the siren sounds, it will not stop until all alarmed partitions are disarmed. However if the siren is active due to
an alarm from a common area zone, and one of the partitions assigned to this area disarms the system, the siren will
also stop. In case that the alarm is initiated from a common area but continues with zones that are not assigned to a
common area, the siren will not stop until all partitions assigned to the alarmed zones are disarmed.
• In case of a fire in partition 1 and a burglary in partition 2, the siren will sound FIRE. When partition 1 is
disarmed, the siren will sound BURGLAR for the remainder of the siren timeout period.
B5. Partition Status display
Partitions status is indicated in the following manner:
P1:
X P2:X P3:X
Each X value indicates a different partition state, as follows:
R
Ready
N
Not ready
A
Away
H
Home
E
Exit delay
D
Entry delay
-
Not used