EasyManua.ls Logo

Visonic KP-250 - Page 56

Visonic KP-250
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8. Periodic Test by User Code
54 D-304269 KP-250 PG2 User’s Guide
Z01 IS ACTIVATE
Z01 CONTACT
Once the device has been activated, the display will change accordingly.
12.
Click to scroll through the list of all untested devices.
9
13.
DEVICE TESTS END
When all devices have been activated, the display reads [DEVICE TESTS END]
followed by [HH:MM READY].
HH:MM READY
Additional Information (Periodic Test)
1
Display shown in disarm state when all zones are secured (00:00 or other digits show present time).
2
If you have not already changed your personal code number, use the default setting – 1111.
3
If the INSTALLER CODE is used to enter the Periodic Test instead of the USER CODE, the devices LED will
also provide the link quality indication – refer to Chapter 4 of the KP-250 PG2 Installer’s Guide, Periodic Test
by Installer Code.
4
To skip the SIRENS TEST and select the other devices TEST, press .
5
The Periodic test can be performed on a maximum of two wireless sirens (including one internal sounder) and
the sirens of enrolled smoke sensors. Outdoor sirens are activated with low volume.
6
If no temperature sensor is enrolled in the system, the display reads
"NO EXISTING DEV.
".
7
The displayed temperature can be in Celsius or Fahrenheit according to the programmed settings of the
Temperature Sensor.
8
To activate system devices during the "Periodic Test"; make sure the device LED lights when activated:
Contact sensor:
Open or close the door or window protected by the contact.
Motion sensors:
Perform a "walk test" of the detector as explained in the detector's datasheet.
Smoke sensors:
Perform a "Diagnostic test" as explained in the detector's datasheet.
Keyfob:
Activate any of the keyfob buttons.
Keypads:
Press the keypad’s
button.
Other devices:
In general, follow the "Diagnostic Tests" described in the device's datasheet or activate any
of its functions.
9
a. Three seconds after the device is displayed, the device LED blinks to assist you to identify ("it's me").
b. To end the session, press the button until the display reads [<OK> TO LEAVE] then press .

Table of Contents

Related product manuals