Technical data
Extra C-Tap C-Tap (tall)
Height
16.1 in
Depth 10.6 in
Diameter 1.4 in
Dispensing height 13.0 in
Weight 5.5 lb
Extra I-Tap I-Tap (small) I-Tap (tall)
Height 15.2 in 17.8 in
Depth 5.9 in 5.9 in
Diameter 2.8 in 2.8 in
Dispensing height 10.2 in 13.0 in
Weight 4 lb 5 lb
Technical conditions EXTRA SERIES
Voltage 120 V
Frequency 60 Hz
Inlet water pressure, max. 0.6 MPa / 87 psi
Inlet water pressure, min. 0.25 MPa / 36 psi (at 0.5 gal/min waterow)
System operating inlet water
pressure
0.4 MPa / 58 psi (at 0.5 gal/min waterow)
Max. relative humidity 60%
Inlet water temperature 41 – 77 °F
Optimal surrounding
temperature range
60 – 89 °F
Height above sea level < 6,500 ft
Protection Class
/ I
Cooler-carbonator EXTRA SERIES
Width 10.7 in
Height 19.3 in
Depth 15.9 in
Weight 84 lb
Current, max. 2.4 A
Power consumption, max. 510 W
Cooling performance 22.5 gal/h
CO
2
operation pressure 0.45 MPa/65 psi
Flow rate 0.5 gal/min
Refrigerant: R290 1.9 oz (56 g)
Noise emission < 60 dB (A)
Boiler Medium
Width 9.1 in
Depth 9.2 in
Height 16.3 in
Weight 17.2 lbs
Flow rate 0.3 gal/min
Current, max. 11.7 A
Power consumption, max. 1,400 W
Heating performance 3.2 gal/h