2 | EN
The Extra series
The VIVREAU Extra product range
includes the Extra C-Tap and Extra
I-Tap with a cooling capacity of 85l/h
(22.5 gal/h).
The Extra I-Tap product range pro-
vides unchilled still, chilled still, chilled
semi-sparkling and chilled sparkling
water. Depending on the performance
option, the Extra C-Tap product range
provides unchilled still, chilled still,
chilled semi-sparkling, chilled spar-
kling and hot water.
ThermalGate
The outlet of the water systems is
usually completely unprotected and
exposed to the environment. Germs
settle on the wet water tap, and with-
out appropriate mechanisms this may
lead to a retrograde contamination.
The ThermalGate™ protects from con-
tamination through external inuences.
The tap outlet will be automatically
heated up at intervals and therefore
thermally disinfected.
VIVREAU HygienePlus
VIVREAU HygienePlus is an exclusive
3 zone protection, only available at
VIVREAU. It is designed for environ-
ments where hygiene is of the utmost
importance, and consists of three key
elements:
1. The inlet water lter includes pre-
lter, activated carbon and hollow-
ber membrane technologies. The
lter reliably retains tested bacteria
(acc. to AST-MF-838) and other
health-hazardous contaminants,
such as cysts (in line with NSF 53).
It also improves the taste of water
by lowering the amount of chlorine.
2. The VIVREAU CLARITY X3 – lo-
cated directly upstream of the tap
outlet – contains an asymmetric
double-layer membrane that retains
99.99999% of remaining bacteria
(acc. to ASTM F838) and 99.95%
of cysts (acc. to NSF53) before the
water is dispensed.
3. VIVREAU’s ThermalGate™ au-
tomatically heats the tap outlet
at regular intervals. This protects
against retrograde contamination
from external sources, such as
physical contact (e.g. touching the
tap) and droplets (e.g. from sneez-
ing or coughing).
EN | 3
General Information Extra Series
This instruction manual is valid for the following products:
Extra I-Tap still & sparkling:
ThermalGate VIV E 85 I-33-C2-TG-J-CU NA /
VIV E 85 I-26-C2-TG-J-CU NA
HygienePlus VIV E 85 I-33-C2-HP-J-CU NA /
VIV E 85 I-26-C2-HP-J-CU NA
Extra C-Tap still & sparkling:
ThermalGateVIV E 85 C-33-C2-TG-M CU NA
Extra C-Tap still, sparkling & hot:
ThermalGateVIV E C-33-C2HM-TG-M CU NA
Naming explanation:
VIV VIVREAU
E “Extra” undercounter water dispenser
I/C Tap shape
33/26 Dispense height
C2 Unchilled/chilled still + chilled semi-sparkling/
sparkling water option
HM Hot water option with Boiler M
TG ThermalGate
HP Hygiene Plus
J/M Version no.