Vogels Autogas Systems VGI Hardware Manual System Description and Installation
VGI Technical Manual 2014-01-14.pdf Pagina 10 van 44
1.6.2 Pressure regulator Landi IG1
The IG1 pressure regulator is a two-stage type. It is heated with engine heat by the engine coolant. The integrated
valve (1 to 3) also filters incoming gas. The pressure regulator adjusts the output pressure to just 1.0 bar (100 kPa)
above the pressure at the compensation port (6) (MAP). The first stage has an operating pressure of 1.6 bar above
atmposperic pressure. The second stage ensures further pressure reduction and is adjustable.
Specifications:
First stage operating pressure:1.6 bar (160 kPa) relative
Second stage operating pressure:.1.0 bar (100 kPa) rel.
Nominal flow volume:.......................................40 Nm3/h
Working temperature:……………………… -20 to 120 °C
Pressure relief flow valve:....................4.5 bar (450 kPa)
Homologation LPG No.:....................... E13 67R-010025
Shut-off valve specifications:
Type:…………………….…MED Type 71
Coil tension:………………….…..12V DC
Power of coil:……………………..….11W
Normally:……………………….…..Closed
Homologation LPG No.:.E4 67R-0193001
The IG1 pressure reducer is available in 3 versions:
IG1 Normal: until engine power of 160 kW.
IG1 Maggiorato: until engine power of 200 kW
IG1 Super Maggiorato: until engine power of 280 kW
Legend:
1) LPG inlet port
2) Filter
3) LPG flow valve
4) LPG outlet port
5) Second stage pressure adjustment
6) MAP connection
7) Water inlet and outlet port
8) Fixing points
A: Pressure Regulator
B: Filter-unit
C: Injector rail
D: Nozzles
E: MAP-connection
F: Inlet manifold
G: Gas inlet
H: Gas Tube 14mm
I: Gas Tube 14mm
L: Gas Tube 6mm
M: MAP Tube
N: Water heating tubes