Model DMTC22KW
Domestic Charger AC 22kW
44
7.2. Initialization errors
The following errors may appear when turning on the Station:
The monitor does not fire: it may be due to a monitor failure. Check and replace the
monitor if necessary.
Earth leakage failure: it may be due to a higher current than expected. Disconnect
the power supply to force it to restart. If the message continues to appear, contact
Volt-E.
The charger does not start charging: check the emergency stop button. Turn the
emergency button off to allow the charger to function normally.
7.3. Connection inspection
This type of equipment is for electric vehicles, and the AC connection cables must be
regularly inspected, especially the wiring and ground conductors connected to the
distribution board and the charger terminal. Check that the screws and cables are
properly tightened to the specified touch.
7.4. Solution of problems
General
0x0001
Emergency button pressed
0x0002
DC + and GND insulation failure
0x0003
“DC- and GND insulation failure
0x0004
isolation device failure
0x0014
Above maximum current