50
e) Activate/deactivate limit alarm pause function
In order to activate/deactivate the limit alarm pause function during recording, the limit alarm must be enabled dur-
ingconguration(pleasereferto"“MEASUREMENT”options-“ALARMSETTING”"onpage42).
DL-260A: Current (mA) DL-250V: Voltage (V)
long press
ENTER
pause on
mA
long press
ENTER
pause on
V
long press
ENTER
pause off
mA
long press
ENTER
pause off
V
Activate/deactivate limit pause function by holding and pressing button ENTER (7) for few seconds.
Once the alarm pause function is activated/deactivated, the latest measurement is shown in the display.
Recorded values during activated pause function are shown in the report’s graph as usual. However, it is
clearly indicated in the graph when and for how long the pause function was activated.
Whenthelimitpausefunctionisactivatedduringrecording,therewillbenotanyalarmindicator“√”or“X”.
LED-alarm status, maximum vand Minimum values will not be updated.
f) Read maximum/minimum measurements
DL-260A:
Current (mA)
mA
Short
press
ENTER
mA
Short
press
ENTER
mA
DL-250V:
Voltage (V)
V
Short
press
ENTER
V
Short
press
ENTER
V
Press button DOWN (5) in the function menu several times until you reach the record from which you wish to read
themaximumandminimumreadings,e.g.current“mA”(DL-260A)orvoltage“V”(DL-250V),
Press button ENTER (7) to enter maximum and minimum reading mode.
Press button ENTER (7) to switch between maximum and minimum reading in that selected record.
Press button DOWN (5) to leave the maximum and minimum reading mode.
“MAX”indicatesmaximumand“MIN”indicatesminimumvalue.
Maximum and minimum measurements are recorded from the moment recording starts.
For latest readings, the data logger will sense and update the value on display, unless the limit pause func-
tion has been activated. Maximum and minimum readings will stop updating once the device stops logging.