Fire Extinguishing System
Separate relay and equipment
Fault
codes will appear if the fire-extinguishing system
input is activated:
Red alarm/buzzer
Flash code 299
(internal fault in EVC system)
VODIA/EVC display fault
Serious communication fault, PCU
PSID 200, FMI: 8
Serious communication fault, PCU
PSID 200, FMI: 9
Internal ECU communication fault, PCU
SID 231, FMI: 2
For further information, please refer to EVC specific
litterature.
Recommended installation
Active (+) at stop (energized to stop)
1 Pin 1 R (+)
2 Pin 2 SB (-)
3 Accessory cable kit, 10 m (3.5 ft.)
4 Fire extinguishing system
5 Main switch (+) or accessory relay (ignition switch)
P0011385
87a
30
87
(+)86
(-) 85
1
2
3
4
5
P0011567
Installation, Fire Extinguishing System
140 47704162 10-2014 © AB VOLVO PENTA