BA ET18, 20, 24 en* 1.5 * et18_20_24i400.fm 4-43
Putting into operation 4
Battery master switch
NOTICE
Possible damage to the electronics due to improper actuation of the
battery master switch!
Do not operate the battery master switch with a running engine.
Actuate the battery isolator switch no sooner than two minutes after
shutting down the engine.
From serial number WNCE0801KPAL01357, the ET20 has a battery
isolator switch as a standard. The ET18/ET24 can be optionally outfitted
with this.
Actuate the battery isolator switch:
If the vehicle is parked for longer periods of time (e.g. over the
weekend).
If the vehicle is to be particularly protected against unintentional
starting.
If required by national and regional provisions.
The battery isolator switch A is located on the battery below the left side
flap.
Interrupt the electric power supply:
Flip up the battery isolator switchA and remove from theB positive
terminal.
Establish the electric power supply:
Set the battery isolator switch A to the positive terminal B and fold down.
Abb. 111
Fig. 112
A
Fig. 113
B
A