BA E14 track en* 1.3 * E14t_13_400.fm 4-55
Putting into operation 4
1. Insert the starting key.
2. Turn the starting key to position 1.
3. Indicator lights A – D are illuminated for a few seconds.
If an indicator light does not function, contact a Wacker Neuson service
center.
4. Turn and hold the starting key in position 2 until the indicator light for
preheating (E) goes out.
The indicator lights engine oil pressure (F) and alternator charging
(C) are illuminated.
5. Turn the starting key to position 3 until the engine runs.
All indicator lights go out.
If the engine does not start after 20 seconds:
6. Interrupt the start procedure and repeat it after two minutes.
If the engine still does not start after a few tries, contact a Wacker
Neuson service center and have the error rectified.
7. Release the starting key as soon as the engine runs.
Warm-up phase of vehicle
After the engine has started, allow it to warm up at slightly increased idling
speed until the coolant reaches its operating temperature of about 80 °C
(176 °F).
Do not let the vehicle warm up at standstill.
Check for unusual noise, exhaust color, leaks, malfunctions, or damage.
In case of malfunctions, damage, or leaks:
Secure the vehicle, park it and find out the cause for the damage and
have it repaired.
Information
Fold up the control lever base after shutting off G the engine.