BA E14 track en* 1.3 * E14t_13_710.fm 7-67
Maintenance 7
Manual Regeneration/Standstill regeneration
ET65/404F-22T: Indicator light D illuminates.
ET90/TCD 2.9 DPF: Indicator light D blinks.
A regeneration must be started.
Information
To be able to start a regeneration, the coolant temperature must be at least
70°C/158°F (ET65/404F-22T) or at least 60°C/140°F (TCD 2.9 DPF).
The indicator light G can blink depending on the loading condition.
4 Start manual regeneration/standstill regeneration
1. Drive the vehicle out of the danger zone and into a safe area.
2. Press the dozer blade against the ground (only ET90/TCD 2.9 DPF).
3. Actuate the parking brake J (only ET90/TCD 2.9 DPF).
The engine must be at idling speed (only ET90/TCD 2.9 DPF).
4. Hold touch button Regeneration pressed down as long in position
3 (ET65/404F-22T) or 5 (TCD 2.9 DPF) , until indicator light D illuminates.
ET90/TCD 2.9 DPF: The engine speed increases to approx. 2000 rpm
The indicator light F also illuminates during the regeneration.
Information
Manual regeneration or standstill regeneration has the following effects on
vehicle operation:
ET65/404F-22T: work may be performed with the vehicle.
ET90/TCD 2.9 DPF: vehicle may not be driven or used for work. Do not
leave the vehicle during regeneration.
Fig. 322
ET90
ET65
Y
D
G
F
3
5