Maintenance
Hydraulic oil supply
BA RD24_RD28 en us 06
117
1. Switch off diesel engine and remove ignition key.
2. Allow machine to cool down to a temperature under 30 °C (86 °F).
3. Unscrew the cup-shaped housing [A].
4. Unscrew the filter insert [B] from the filter head and replace with a
new one.
5. Clean the inside of the cup-shaped housing, screw it back to the filter
head and tighten.