RD 27 Maintenance
wc_tx000815gb.fm 51
* Use whichever comes first, calendar time or service hours.
Exciter shaft bearings Re-pack
Fuel system water separa-
tor element
Replace
3
Fuel tank cap and strainer Clean
3
Hydraulic oil filter Change
3
Radiator/hydraulic oil
cooler
Clean
3
Shock mounts Check
3
Battery Check
3
Control lever tension Adjust
3
Engine: mounting bolts,
valve lash, cylinder head
bolts, exhaust system
Inspect
3
Hydraulic oil Change
3
Hydraulic tank breather Replace
3
Hydraulic tank strainer Clean
3
Radiator filler cap Clean
3
ROPS and mounting hard-
ware
Inspect/
torque
3
Engine water pump Check
3
Fuel injector Test
3
Cooling system coolant Change
Temperature
regulator
Replace
Interval* (hours of service)
(10) (100) (250) (500) (1000) (3000) (12,000)
Item Task
Daily 2
weeks
3
months
Yearly Yearly 3
years
6
years