EPG-SPRINT / EPG-SPRINT X
SERVICE MANUAL
VERSION 09/2017 ORDER NUMBER DOC2309350
10.1 PLANT LEVEL PARAMETERS
10 PLANT LEVEL
The following parameters are available at plant level:
Parameter Display Description
C41 "PrE" Pressure = measure operating pressure inside the equipment
(readjust pressure regulator, see Chapter 10.3)
C42 "AFA" Calibrate air outlets: Indication of o set values, calibrate and manually
adjust the correction factors, check air controllers individually
C43 "rES" Master reset: Reset entire EEPROM to WAGNER's default setting
C44 "HVA" High-voltage calibration
C45 "AFo" Default setting of o set for air channels
This is a default setting that must be performed in case of a sensor or PCB
replacement.
The menu is also used for controlling the setting.
C46 - C50 "---" Not assigned; this is indicated by "---"
Incorrect calibration!
ATEX/FM approval ceases to apply.
Only allow a technical expert from a tested WAGNER service
department to undertake calibration.
DANGER

Table of Contents

Other manuals for WAGNER EPG-Sprint X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the WAGNER EPG-Sprint X and is the answer not in the manual?

WAGNER EPG-Sprint X Specifications

General IconGeneral
BrandWAGNER
ModelEPG-Sprint X
CategoryControl Unit
LanguageEnglish

Related product manuals