EasyManuals Logo
Home>WAGNER>Control Unit>EPG-Sprint X

WAGNER EPG-Sprint X Original Service Manual

WAGNER EPG-Sprint X
108 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #74 background imageLoading...
Page #74 background image
74
EPG-SPRINT / EPG-SPRINT X
Tribo Corona
5
4
3
2
1
120
100
80
60
40
30
20
15
10
5
μA
μA
2x
kV
90
80
70
60
50
40
30
20
10
100
P_01271
24
19
16
15
312927
25
EPG
SPRINT X
0
%
kV
80
60
40
20
100
Tri Cor
5
4
3
2
1
120
80
40
20
10
2.0
μA
P_01830
24
19
16
15
312927
25
SERVICE MANUAL
VERSION 09/2017 ORDER NUMBER DOC2309350
10.5 PARAMETER C43, MASTER RESET
Purpose:
To reset all values in the memory.
All air and high-voltage calibration values, all recipes and con guration values are reset
to a basic value.
Note:
We would not recommend using this function in the  eld as the air and high voltage have
to be recalibrated.
Procedure:
1. Access parameter C43 (refer to Chapter 10.2).
2. Press the "Characteristic Slope" button 31. "no" is displayed on LED display 19.
3. Turn Universal rotary controller 24 one step clockwise, "rES" is indicated in the LED
display 19.
4. Press "Additional Recipes" button 25 for 1 second. The display goes out brie y as a
con rmation.
5. Press "Standby" button 15 to exit the con guration.

Table of Contents

Other manuals for WAGNER EPG-Sprint X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the WAGNER EPG-Sprint X and is the answer not in the manual?

WAGNER EPG-Sprint X Specifications

General IconGeneral
BrandWAGNER
ModelEPG-Sprint X
CategoryControl Unit
LanguageEnglish

Related product manuals