SERVICE MANUAL
VERSION 09/2017 ORDER NUMBER DOC2309350
10.5 PARAMETER C43, MASTER RESET
Purpose:
– To reset all values in the memory.
All air and high-voltage calibration values, all recipes and con guration values are reset
to a basic value.
Note:
We would not recommend using this function in the eld as the air and high voltage have
to be recalibrated.
Procedure:
1. Access parameter C43 (refer to Chapter 10.2).
2. Press the "Characteristic Slope" button 31. "no" is displayed on LED display 19.
3. Turn Universal rotary controller 24 one step clockwise, "rES" is indicated in the LED
display 19.
4. Press "Additional Recipes" button 25 for 1 second. The display goes out brie y as a
con rmation.
5. Press "Standby" button 15 to exit the con guration.