Section Type of inspection Requirements Inspection
by
Type of inspection Inspection
interval
1 Checking the eectiveness of
technical ventilation
Checking the eectiveness of
technical ventilation
TP/SP
ME
Measurements of air ow speed/
air quantities
Check the dierential pressure
indicator.
continuously
2 Link between technical ventilation
equipment and high voltage,
compressed air and coating
material supply
The technical ventilation should
be interlocked such that the
powder feed and high voltage
cannot be switched on, while the
technical ventilation is not working
eectively.
SP
FT
Test whether the system is safely
stopped and the product supply,
supply air, and high voltage
are switched o when the
ventilation is shut down.
annually
3 Parts carrying high voltage outside
the spray area
Parts carrying high voltage outside
the spray area must be routed such
that discharges which put people at
risk do not occur.
SP
FT
Inspect and test (e.g., by
measurement) whether all parts
carrying high voltage do not
result in discharge which puts
people at risk.
weekly
Legend:
MF = Manufacturer
ER = Employer
SP = Skilled person
FPO = Fire prevention ocer
ELT = Electrician
TP = Trained person
FT = Function test
ME = Measurement
OC = Organization check
VI = Visual inspection
CM = Constant monitoring
TT = Technical testing

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the WAGNER EPG-SPRINT XE and is the answer not in the manual?

WAGNER EPG-SPRINT XE Specifications

General IconGeneral
BrandWAGNER
ModelEPG-SPRINT XE
CategoryPaint Sprayer
LanguageEnglish

Related product manuals