95
EPG-SPRINT XE
OPERATING MANUAL
VERSION 09/2017 ORDER NUMBER DOC2354913
Parameter Value Description
C21
Vibrator motor controller
after-run
10 s
(factory setting)
Vibrator motor overruns for 10 seconds.
OFF Vibrator motor is not controlled; always o.
ON Vibrator motor is always switched on.
1 s - 240 s Vibrator motor is switched on with the
manual gun's trigger lever and overruns for
X seconds; can be set from 1 second to 240
seconds.
C22
Hose ushing (dosing air
without feed air)
OFF
(factory setting)
Hose ushing switched o.
1 s - 10 s Hose ushing time overrun in seconds.
C23
Hose ushing intensity of
dosing air
100%
(factory setting)
Hose ushing intensity 100%.
1%–100% Hose ushing intensity from 1% to 100%.
C25
Tribo current minimum
monitoring
OFF
(factory setting)
Tribo current is not monitored.
0.1 µA - 5 µA If the Tribo current does not reach the set
values for more than 10 seconds, a warning
is issued (see Warnings and Fault Messages).

Table of Contents