5.3 OPERATING ELEMENTS ON CONTROL CABINET
Auto
100
90
80
70
60
10
20
30
40
50
10
9
8
7
6
1
2
3
4
5
IP 5000
14
6
109 11
P_00006
87
3
5
2
Designation
1 Button: "ON/OFF"
2 LED ashes if no release has been issued by the powder center.
The buttons are then locked.
3 Button: "Cleaning ON/OFF"
4 Button: "START / STOP" (manual operations)
5 LED display: "Service Interval" (cycle counter) *
6 LED display: "Cleaning Time" *
7 Button: "Reduced Flow Rate"
8 Button: "Full Flow Rate"
9 Display for control via level monitoring
10 Fault display (LED lights up)
11 Pressure gauge for piston air
The LEDs also light up when the pump is switched o with "ON/OFF" button 1
(serves for 24 VDC voltage monitoring).
5.4 EXTENT OF DELIVERY
Order no. Designation
1 241004 IP 5000 powder pump
1 2386088 IP 5000-USD powder pump
The standard equipment includes:
1 241942 Declaration of Conformity
1 241935 Operating manual, in German
1 see Chapter 1.3 Operating manual in local language
For special versions the delivery note applies.