7.6 CYCLE COUNTER
The powder pump is equipped with a cycle counter, which triggers a warning signal
(fault LED ashes) after reaching a set number of pump cycles, prompting replacement of
the valve and pump hoses.
After replacing the pump and valve hoses, the cycle counter must be reset.
Auto
100
90
80
70
60
10
20
30
40
50
10
9
8
7
6
1
2
3
4
5
IP 5000
1
P_00036
23
Work steps:
1. Switch powder pump o with "ON/OFF" button 1.
2. Press buttons 2 and 3 simultaneously until the LED ashes quickly
(press button for at least 5 sec.).
The cycle counter is now reset, the LED bar is back to 100%.
7.7 CONDITIONS FOR OPERATING THE PUMP
No ushing is possible during the pump operation. Pressing the "Cleaning" button will