28
EDITION 08/2021
ORDER NUMBER DOC241936
IP 5000
6.7 HOW TO HANDLE THE HOSE COUPLING
3
2
1
P_00975
4
Loosening the hose coupling:
Work steps:
1. Lift the O-ring 1 out of the groove and slide it to the front.
2. Turn the locking nut 2 in a clockwise direction up to the stop and pull the hose
coupling 3 out of the coupling piece 4.
Connecting the hose coupling:
Work steps:
3. Insert the hose coupling 3 into the coupling piece 4 and turn the locking nut 2
counterclockwise up to the stop.
4. Press the O-ring 1 into the groove again (securing function).
Note:
Slide the powder hose onto the hose coupling as far as possible (up to the stop)!
6.8 GROUNDING
For safety reasons the system must be properly grounded. WAGNER recommends the use
of a copper cable of at least 4 mm² with sucient mechanical stability.
A poorly grounded powder pump will damage the controller!
6.9 START UP
WARNING
Incorrect commissioning!
Risk of injury and damage to the device.
Trained and authorized personnel may only carry out commissioning.
We recommend that commissioning is carried out by WAGNER personnel.