9 TROUBLE SHOOTING AND SOLUTION
DANGER
Incorrect maintenance/repair!
Danger to life and equipment damage.
WAGNER devices, protective systems and safety, monitoring and control equipment
may only be serviced/repaired as dened in Directive 2014/34/EC (ATEX) by trained
WAGNER service personnel or skilled persons in accordance with TRBS 1203!
Note national regulations!
Service, repair or replacement of devices or parts of devices may only be performed
outside the hazard area!
Malfunction Cause Solution
Powder pump does not deliver No release by powder center Switch on ventilator in powder
center
Pump or valve hose defective Replace the hose
Fault LED lights up Maximum number of pump
cycles reached
Replace pump and valve hoses
Reset cycle counter
(see Chapter 7.6)
Inadequate powder discharge Cratering in the suction system Top up powder and check
powder feed
Hoses kinked Lay hoses rounded, not bent
Check piston air pressure
Check service indicator
Check uidization Set correct uid air quantity