37
EDITION 08/2021
ORDER NUMBER DOC241936
IP 5000
7.5.9 FUNCTION 7 "LEVEL CONTROLLER"
The level controller serves to guarantee a consistent lling level in the powder tank.
For this purpose an external level probe is connected, which sends the relevant signal to
the powder pump controller. When the level controller is switched on, the "Auto" display
ashes on the powder pump control panel.
P_04314
1
2
3
Designation
1 Level sensor
2 Filling level according to level controller time
3 Minimum
Internal LED display Function
No LED lights up Function deactivated (factory setting)
LED 1 lights up Signal 1 Pump on
Signal 0 Pump o (switch function)
LED 2 lights up Signal 1 Pump runs for 10 sec., if signal is subsequently still
present, pump runs for another 10 sec. until signal = 0
LED 3 lights up Same function as LED 2 with feed time of 30 sec.
LED 4 lights up Feed time 45 sec.
LED 5 lights up Feed time 60 sec.
LED 6 lights up Feed time 75 sec.
LED 7 lights up Feed time 90 sec.
LED 8 illuminate Feed time 120 sec.
7.5.9.1 EXAMPLE FOR LEVEL SENSOR'S CONNECTION DIAGRAM
XST9
1 2 3 4 5 6 7 8 9 10
PE
11
1214
A1
A2
P_04315
2
1
Designation
1 Plug
2 Level sensor