36
EDITION 08/2021
ORDER NUMBER DOC241936
IP 5000
7.5.8 SETTING EXAMPLE
100
90
80
70
60
50
40
30
20
10
P_04310
The "Powder center" operating mode is activated in the example. 4 LEDs
light up on the display, which means that another 800 000 pump cycles
can be executed until the fault message appears
(factory setting 2 000 000 cycles - 800 000 possible cycles = 1 200 000 cycles
have been executed).
100
90
80
70
60
50
40
30
20
10
P_04311
After the display has changed to setting status, the LED lights up at value 50
(factory setting 2 000 000 with maximum 4 000 000 pump cycles).
100
90
80
70
60
50
40
30
20
10
The setting value is increased to 2 400 000 cycles by pressing the A+ button.
100
90
80
70
60
50
40
30
20
10
P_04313
After exiting setting mode 5 LEDs light up, which means that another
1 200 000 cycles can be executed
(2 400 000 possible cycles - 1 200 000 completed cycles =
1 200 000 possible cycles).