EasyManua.ls Logo

WAGNER IP 5000 - Storage Conditions for Pump and Valve Hoses

WAGNER IP 5000
88 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
49
EDITION 08/2021
ORDER NUMBER DOC241936
IP 5000
4
P_00015
3
2
5
*
28. Fit lower valve housing (4) and Y-piece (3) to the bottom of the pump body (5) and
fasten with screws (2).
Evenly tighten screws (2) alternately crosswise. (6 Nm; 4.425 lb ft).
* To facilitate assembly, two longer screws (order no. 9907014) are provided,
which must be replaced with the shorter screws when assembly is complete.
29. Push powder hoses onto the upper and lower hose tting and fasten with hose clips.
30. Insert air lines into the upper and lower valve blocks.
31. After successful execution of the tightness check and resetting of the cycle counter
(see Chapter 7.6), the powder pump can be recommissioned.
8.3 STORAGE CONDITIONS FOR PUMP AND VALVE HOSES
The materials of pump and valve hoses are not resistant to ageing.
Therefore, dry pump and valve hoses and store at room temperature, protected from light.
The hoses are labeled with the date of manufacture. The hoses should no longer be used
after a period of 24 months!