46
EDITION 08/2021
ORDER NUMBER DOC241936
IP 5000
View from top
P_00013
A
The pump hoses must not be mounted twisted (observe ridges A).
Press hose collar at the top and bottom against the wall with your ngers.
9
5
8
P_00014
17. Attach hose ange 9 to the bottom of the pump body 5 and fasten with screws 8.
Do not damage the pump hoses.
Evenly tighten screws 8 crosswise (5 Nm; 3.7 lb ft).
18. Carefully screw connections 1 into the lower ange.
9
5
8
P_00010
19. Attach hose ange 9 to the top of the pump body 5 (observe hole pattern) and
fasten with screws 8.
Do not damage the pump hoses.
Evenly tighten screws 8 crosswise (5 Nm; 3.7 lb ft).