EasyManua.ls Logo

WAGNER PEM-C4-Ergo - 5.3 GROUNDING

WAGNER PEM-C4-Ergo
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
19
PEM-C4-Ergo.
OPERATING MANUAL
VERSION 02/2009 ORDER NUMBER DOC2305054
5.3 GROUNDING
For safety reasons, the spray gun must be properly grounded. This occurs through the
electrical cable.
Good grounding of the workpiece is also necessary for optimum powder coating.
A poorly grounded workpiece causes:
Dangerous electric charging of the workpiece
Very bad wrap around
Uneven coating
Backspraying to the spray gun, i.e. contamination
Sparks between workpiece and conveyor hooks (hangers) can occur if hooks or
other hanger parts are not completely cleaned! These sparks can cause heavy radio
frequency interference (Electro-magnetic compatibility = EMC).
WARNING
Heavy paint mist if earthing is insufficient!
Risk of poisoning
Insufficient paint application quality
Earth all unit components.
Earth the workpieces being painted.
SIHI_0003_GB

Table of Contents

Related product manuals