26
PEM-C4-Ergo.
1
2
3
5
P_00591
P_00592
P_00593
OPERATING MANUAL
VERSION 02/2009 ORDER NUMBER DOC2305054
7.2 CLEANING THE SPRAY GUN AND DISMANTLING THE FAN SPRAY NOZZLE
Procedure:
1. Unscrew the outer nut 1 from the spray gun housing 5.
2. Pull the fan spray nozzle 2 off the electrode holder 3.
3. Carefully pull the electrode holder 3 out of the spray gun
housing 5.
Hint:
Do not damage the electrode holder, when pulling out and
inserting.
4. Remove powder residue from the parts removed and from the
spray gun.
Hint:
Never place the spray gun or parts of the spray gun in cleaning
agent.
As a rule you only need to check the protective wedge for wear
and replace it as necessary.
New protective wedge
Worn protective wedge
We recommended replacing the protective wedge.
In the next section it is described how the protective wedge is to be dismantled and
inserted.