9.6 Fitting a Standard Kabin Pak Vertical Flue Adaptor
1. Remove the 2 screws connecting the flue main body to the Kabin Pak and lift off. It
may be necessary to break the seal between the flue main body and the top of the flue
pipe.
2. Ensure that the gap between the existing flue pipe and top of the Kabin Pak is properly
sealed with high temperature silicone sealant.
3. Once the flue main body has been removed fit the Kabin Pak adaptor (KPA) into
position and secure with the 2 screws. A 5” conventional flue can now be attached.
9.7 Slimline Kabin Pak