Product Reference Guide
85
1D SYMBOLOGIES
1D Code Selection
The reader supports the following 1D symbologies (bar code types). See "2D Symbologies"
starting on page 177
for 2D bar codes. Symbology-dependent options are included in each
chapter.
• Disable All Symbologies, page 86 • GS1-128, page 123
• Code EAN/UPC, page 87 • Code ISBT 128, page 124
• UPC-E, page 90 • Interleaved 2 of 5 (I 2 of 5), page 127
• GTIN Formatting, page 93 • Interleaved 2 of 5 CIP HR, page 132
• EAN 13 (Jan 13), page 94 • Follett 2 of 5, page 132
• ISSN, page 96 • Standard 2 of 5, page 133
• EAN 8 (Jan 8), page 97 • Industrial 2 of 5, page 137
• UPC/EAN Global Settings, page 99 • Code IATA, page 141
• Add-Ons, page 101 • Codabar, page 142
• Code 39, page 108 • ABC Codabar, page 148
• Trioptic Code, page 114 • Code 11, page 151
• Code 32 (Ital Pharmaceutical Code), page
114
• GS1 DataBar™ Omnidirectional, page
155
• Code 39 CIP (French Pharmaceutical), page
116
• GS1 DataBar™ Expanded, page 156
• Code 39 Danish PPT, page 116 • GS1 DataBar™ Limited, page 161
• Code 39 LaPoste, page 117 • Code 93, page 162
•
Code 39 PZN, page 117 • MSI, page 167
• Code 128, page 118 • Plessey, page 172
Default settings are indicated at
each feature/option with a green arrow. Also reference
Appendix B, Standard Defaults for a listing of the most widely used
set of standard factory set-
tings. That section also provides space to record any custom settings needed or implemented
for y
our system.
To set most features:
1. Scan the ENTER/EXIT PROGRAMMING bar code at the top of appli
cable programming
pages.
2. Scan the correct bar code to set the desired
programming feature or parameter. You may
need to cover unused bar codes on the page, and possibly the facing page, to ensure that
the reader reads only the bar code you intend to scan.
3. If additional input parame
ters are needed, go to Appendix D, Keypad, and scan the appro-
priate characters from the keypad.
NOTE
Additional information about many features can
be found in the “References” chapter.
If you make a mistake before the last character, sc
an the CANCEL bar code to abort and
not save the entry string. You can then start again at the beginning.
4. Complete the programming sequence by scanning the ENTER/EXIT PROGRAMMING bar
code to exit Programming Mode.