Check the blades (for damage)
Inspect the spreader ps (for damage)
Check the control handle including the rocker switch (funcon)
Check the handle (fastened securely)
Check the protecve housing (damage)

Check the piston rod (damage)
Check the control handle including the rocker switch (funcon)
Check the pressure elements (damage)
Check the guide secon (damage)
8.3 Shutdown (end of work)

Aer work is over, the blade ps must be placed one above the other to prevent injury.
However, never close the cuer’s blades completely, as this would generate tension
in the appliance.

Once work has nished, the cylinder's piston rod must be retracted almost enrely in order
to relieve the appliance's hydraulic pressure.

Once work has nished, the spreader arms must remain slightly open in order to relieve
the appliance's hydraulic pressure.