 Possible cause Remedy
Appliance does not reach full
performance
Rocker switches not completely
pressed to the side
Press the rocker switches completely
to the side
Combi tool moves in opposite
direcon under load
Check valve defecve
Have the appliance checked by an
authorised service centre.
Blades are loose and gape apart during
cung
Blade not aached to the shear head
as specied
Repair work by an approved workshop
Blade opening below target value Shearing head sengs altered Repair work by an approved workshop
Combi tool opening width below
target value
Shearing head sengs altered Repair work by an approved workshop
Pressure build-up despite movement
(open - closed) without a load
Hex nut / central bolt too ght Repair work by an approved workshop
Blade chipping
Blades damaged e.g. from cung
high-strength materials
Re-sharpenable to about 2 mm (see
repair manual) otherwise replace
Cracks in the blades
Blades damaged e.g. from cung
high-strength materials
Have the blades replaced by an
authorised service centre
Rescue equipment does not funcon Baery is dead
Place the baery on the charger.
The displays on the baery and
charger give informaon about
the baery charge status