EasyManuals Logo

Weber GENESIS Replacement Instructions

Weber GENESIS
8 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #6 background imageLoading...
Page #6 background image
16
CHECK FOR GAS lEAKS
m DANGER
Do not use an open flame to check for gas leaks. Be sure
there are no sparks or open flames in the area while you
check for leaks. Sparks or open flames will result in a fire or
explosion, which can cause serious bodily injury or death and
damage to property.
Gas Sources:
NGLP
1
2
4
5
6
3
You will need: a soap and water solution and a rag or brush to apply it.
A) Mix soap and water.
B) Turn on gas supply at source.
C) Check for leaks by wetting fittings with soap and water solution and
watching for bubbles. If bubbles form, or if a bubble grows, there is a leak.
D) When leak checking is complete, turn gas supply off at source and
rinse connections with water.
Check:
E) Main gas line-to-manifold connections (1).
F) Side burner gas line-to-manifold connection (2).
m WARNING: If there is a leak at connection 1 or 2, retighten
the fitting with a wrench and recheck for leaks with soap and
water solution. If a leak persists after retightening the fitting,
turn OFF the gas. DO NOT OPERATE THE GRILL. Failure
to follow dangers, warnings and cautions contained in this
instruction sheet may cause a fire or an explosion resulting in
serious personal injury or death as well as damage to property.
Contact the Customer Service Representative in your area
using the contact information on our web site.
Log onto www.weber.com
®
.
G) Valves-to-manifold connections (3).
H) LP: Regulator hose-to-cylinder connection (4).
I) LP: Regulator hose-to-regulator connection (5).
J) NG: Hose-to-quick-disconnect gas line connection (6).
m WARNING: If there is a leak at connections 3, 4, 5 or 6, turn
OFF the gas. DO NOT OPERATE THE GRILL. Failure to follow
dangers, warnings and cautions contained in this instruction
sheet may cause a fire or an explosion resulting in serious
personal injury or death as well as damage to property.
Contact the Customer Service Representative in your area
using the contact information on our web site.
Log onto www.weber.com
®
.
When leak checks are complete, turn gas supply OFF at source and rinse
connections with water.
m
IMPORTANT: To do a proper leak check, control panel must
be off. After checking for leaks, reinstall control panel, wind
deflector and control knobs.

Other manuals for Weber GENESIS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Weber GENESIS and is the answer not in the manual?

Weber GENESIS Specifications

General IconGeneral
IgnitionElectronic
Main Burners3
Total Cooking Area669 square inches
Fuel TypePropane or Natural Gas
BTU-per-hour Input39, 000 BTU
Side BurnerYes
Sear StationYes
Side Burner BTU12, 000 BTU
Grill TypeGas Grill