Basic Commissioning
No. Illustration Factory Setting
4 System reservation (unalterable). OFF
2. Rotate S2 to the needed value.
Actual station addresses are as shown in the following table:
S3 No.3 S2 Station Address S3 No.3 S2 Station Address
OFF 0 Invalid ON 0 50H
OFF 1 41H ON 1 51H
OFF 2 42H ON 2 52H
OFF 3 43H ON 3 53H
OFF 4 44H ON 4 54H
OFF 5 45H ON 5 55H
OFF 6 46H ON 6 56H
OFF 7 47H ON 7 57H
OFF 8 48H ON 8 58H
OFF 9 49H ON 9 59H
OFF A 4AH ON A 5AH
OFF B 4BH ON B 5BH
OFF C 4CH ON C 5CH
OFF D 4DH ON D 5DH
OFF E 4EH ON E 5EH
OFF F 4FH ON F 5FH
3. Restart the driver to make the settings effective.
Set Station Address for Wise Driver
The setting of station address for Wise driver is done through the panel in front of the driver.
To set station address for Wise driver:
1. Set the value of driver parameter Pr001 Control Mode Setup to 1.
14