Installation and operating instruction
Oil burner WL20/2-C Z
5 Installation
83307702 1/2019-04 La
27-80
Connect oil supply and observe:
do not twist oil hoses
avoid mechanical tension
consider length of hose required for the service position,
do not kink oil hoses (curve radius 1 of 50 mm must be maintained).
If these conditions for connection can not be met:
Adapt oil supply on site.
1
Purge oil supply and ensure it is tight
CAUTION
Oil pump seized due to running dry
Pump could be damaged.
Fill oil supply with oil and purge.
Ensure oil supply is tight.