7 Commissioning
83307702 1/2019-04 La
37-80
7.3 Concluding work
WARNING
Oil leakage from oil pressure measuring devices due to constant load
Oil pressure measuring devices could be damaged and cause environmental pollu-
tion through leakage.
Remove oil measuring devices once commissioning is complete.
If necessary, replace plug switch with 4 pole connection plug.
Check control and safety devices.
Check tightness of oil carrying components.
Enter combustion values and settings in the commissioning record and/or test
sheet.
Mount cover on burner.
Inform the operator about the use of the equipment.
Hand the installation and operating manual to the operator and inform him that
this should be kept with the appliance.
Point out to operator that the installation should be serviced annually.